Diagnostics (Basel, Switzerland)

Fast One-Step Test Using CRISPR to Detect Antibiotic-Resistant Staphylococcus aureus

Updated

Abstract

Visual detection of can be achieved in 20 minutes using a new one-tube detection platform.

  • The platform integrates recombinase polymerase amplification () with the Cas12 system.
  • Sensitivity for the fluorescence method is 10 copies, while the lateral flow test strips (LFS) detect between 10-100 copies.
  • A 100% coincidence rate was observed with the fluorescence method and a 95.7% rate with LFS when compared to qPCR in 23 clinical MRSA samples.
  • This method is designed to be rapid, accurate, and contamination-free for MRSA detection.

Simplified

Key numbers

10 copies
Detection Sensitivity
Lowest detectable DNA concentration using the fluorescence method.
100%
Coincidence Rate for Fluorescence Detection
Coincidence rate for fluorescence-based detection of in clinical samples.
95.7%
Coincidence Rate for Lateral Flow Strip Detection
Coincidence rate for lateral flow strip-based detection of .

Full Text

What this is

  • This research presents a novel one-tube - detection platform for ().
  • Current diagnostic methods are inadequate for rapid point-of-care testing, necessitating innovative solutions.
  • The developed platform enables visual detection within 20 minutes, utilizing both fluorescence and lateral flow strip methods.

Essence

  • The one-tube -CRISPR/Cas12a platform provides rapid and sensitive detection of , achieving a 100% coincidence rate with fluorescence and 95.7% with lateral flow strips compared to qPCR.

Key takeaways

  • The one-tube -CRISPR/Cas12a assay can detect as low as 10 copies of DNA, making it highly sensitive.
  • The platform demonstrated a 100% coincidence rate for fluorescence detection and 95.7% for lateral flow strip detection when validated against clinical isolates.
  • This system is designed for point-of-care testing, requiring minimal equipment and providing results within 20 minutes.

Caveats

  • The lateral flow strip method has a lower detection sensitivity range of 10-100 copies compared to the fluorescence method.
  • The potential for aerosol contamination exists during the lateral flow strip method due to the need to open the tube cap.

Definitions

  • Methicillin-Resistant Staphylococcus aureus (MRSA): A type of bacteria resistant to many antibiotics, causing severe infections.
  • RPA (Recombinase Polymerase Amplification): An isothermal amplification technique used to rapidly replicate DNA.
  • CRISPR/Cas12: A genome editing technology used for targeted DNA detection and modification.

Simplified

Funding

Competing interests

The authors declare no conflict of interest.
PubMed

What Lands in Your Inbox Each Week:

  • 📚7 fresh studies
  • 📝plain-language summaries
  • direct links to original studies
  • 🏅top journal indicators
  • 📅weekly delivery
  • 🧘‍♂️always free